Cetop 3 Standard Performance


Description

These solenoid operated Directional Control Valves (DCV) are for directing and stopping flow at any point in a hydraulic system. The high perfomance can handle upto 80 lpm and 350 bar max pressure depending on the spool type, flow path and coil options selected.

Tech Specs

Description                         Voltage Schematic qty of coils Coil Part Number Max Bar Max Tank Pressure Bar Max Flow Rate LPM IP Rating Weight ea unpacked (kg)
DG4V-3S-0B-M-U-A5-60 110VAC 1 02-101725 350 100 40 65 2.2
DG4V-3S-0B-M-U-ED5-60 240VAC 1 02-111261 350 100 40 65 2.2
DG4V-3S-0B-M-U-G5-60 12VDC 1 507847 350 100 40 65 2.2
DG4V-3S-0B-M-U-H5-60 24VDC 1 507848 350 100 40 65 2.2
DG4V-3S-0C-M-U-A5-60 110VAC 2 02-101725 350 100 40 65 2.2
DG4V-3S-0C-M-U-ED5-60 240VAC 2 02-111261 350 100 40 65 2.2
DG4V-3S-0C-M-U-G5-60 12VDC 2 507847 350 100 40 65 2.2
DG4V-3S-0C-M-U-H5-60 24VDC 2 507848 350 100 40 65 2.2
DG4V-3S-2A-M-U-A5-60 110VAC 1 02-101725 350 100 40 65 2.2
DG4V-3S-2A-M-U-ED5-60 240VAC 1 02-111261 350 100 40 65 2.2
DG4V-3S-2A-M-U-G5-60 12VDC 1 507847 350 100 40 65 2.2
DG4V-3S-2A-M-U-H5-60 24VDC 1 507848 350 100 40 65 2.2
DG4V-3S-2C-M-U-A5-60 110VAC 2 02-101725 350 100 40 65 2.2
DG4V-3S-2C-M-U-ED5-60 240VAC 2 02-111261 350 100 40 65 2.2
DG4V-3S-2C-M-U-G5-60 12VDC 2 507847 350 100 40 65 2.2
DG4V-3S-2C-M-U-H5-60 24VDC 2 507848 350 100 40 65 2.2
DG4V-3S-6C-M-U-A5-60 110VAC 2 02-101725 350 100 40 65 2.2
DG4V-3S-6C-M-U-ED5-60 240VAC 2 02-111261 350 100 40 65 2.2
DG4V-3S-6C-M-U-G5-60 12VDC 2 507847 350 100 40 65 2.2
DG4V-3S-6C-M-U-H5-60 24VDC 2 507848 350 100 40 65 2.2
DG4V-3S-8C-M-U-A5-60 110VAC 2 02-101725 350 100 40 65 2.2
DG4V-3S-8C-M-U-ED5-60 240VAC 2 02-111261 350 100 40 65 2.2
DG4V-3S-8C-M-U-G5-60 12VDC 2 507847 350 100 40 65 2.2
DG4V-3S-8C-M-U-H5-60 24VDC 2 507848 350 100 40 65 2.2
  • Efficient control of greater hydraulic powers without increasing solenoid power consumption.

  •  Installed cost and space savings from higher power/weight-and-size ratios.

  • Increases system efficiency; the result of improved manufacture of spools and bores

  • Installation flexibility resulting from choice of numerous combinations of solenoid connectors and locations

  • Multi-fluid capability without need to change seals.

  • Higher sustained machine productivity and higher uptime because of proven fatigue life and endurance, tested over 20 million cycles.

  • Solenoid coils can be changed quickly and easily without leakage from hydraulic system.

  • Compact, cost effective system design when used with Vickers® SystemStak™ valves and subplates.